PT 310 R3 - Slanted stand for dose measuring

PT 310 R3 - Slanted stand for dose measuring

The device provides a safe and simple method of the manual extraction of 99mTc eluate for the preparation of other radiopharmaceuticals. Its purpose is to reduce the risk of exposure and contamination of employees handling radioactive solutions.

It facilitates maintaining aseptic conditions when preparing solutions for injection application. The device should be used indoors at a fixed location. It should be used on a steady horizontal surface and behind protective lead glass (shield corresponding to approximately 6 mm Pb). With a vial containing 99mTc eluate and with an extraction and a vent needle inserted, the assembled device allows diluting the 99mTc eluate in the vial to the required volume activity. With successive extractions into syringes, it allows drawing and possibly further diluting the 99mTc eluate to the required total and volume activity (when diluting, first draw the appropriate volume of saline solution and then the 99mTc eluate from the device). The activity of the solution extracted into the syringe is measured directly during extaction being displayed directly.

Device description, basic specifications

Main components of the device:

  • Device base - lead shield jacket for the vial, fitted into a plastic base
  • Lead lids for vial positioning and shielding
  • Outer lead covering jacket with an extraction needle clamping jaw
  • Mesuring unit
  • Shield cover for a syringe

Main dimensions:

  • Maximum height: 242 mm
  • Maximum width: 226 mm
  • Maximum depth: 155 mm
  • Maximum vial diameter: 33 mm
  • Maximum vial height: 77 mm
  • Basic weight: 9 kg

Accessories Supplied with the Device

  • Set of spacers to be used under the vial
  • Set of spacers to be used under the shield cover
  • Set of shield cover lids

News and Events

  • EANM'15 Hamburg, DE
    Thursday, 13 August 2015
    On October 11 - 13, 2015     We are proud to present our latest products at EANM 28th Annual Congress…
  • SNMMI 2014 Annual Meeting, USA
    Wednesday, 14 May 2014
    SNMMI 2014 Annual Meeting Society of Nuclear Medicine and Molecular Imaging 2014 Annual Meeting June 7-11, 2014, St. Louis, Missouri,…
  • 14 th Congress of the Polish Society of Nuclear Medicine
    Wednesday, 14 May 2014
    14th Congress of the Polish Association of Nuclear MedicineMay 28-30, 2014 Lublin, Poland     Lynax will be present at…
  • ESRR'14 Pamplona
    Thursday, 17 April 2014
    ESRR'1417th European Symposium on Radiopharmacy and Radiopharmaceuticals April 24-27, 2014 Pamplona, Spain
    Read more »
  • Non-Magnetic Syringe Shield for PET-MR
    Sunday, 27 October 2013
    Lynax has been first on the market offering this material and syringe shields especially. Non-magnetic Tungsten syringe shield is necessary…
News and Events archive