PT 194 R2 - Slanted Stand | PT 173 R3 - Slanted Stand

PT 194 R2 - Slanted Stand | PT 173 R3 - Slanted Stand

PT194R2 Slanted Stand for Activity Distribution with a 6mm Pb Shield

PT173R3 Slanted Stand for Activity Distribution with a 10mm Pb Shield

The device serves for manual extraction and distribution of radioactive solutions, both for administering it directly to patients or for labelling selected substances and/or biological materials, using special kits. It allows maintaining aseptic conditions when working with preparations to be administered by injection.

 

The device provides a safe and simple method of the extraction and distribution of radioactive solutions, both for administering directly to patients and for tagging selected substances and/or biological materials, using special kits.

Brief Description of the Device, Basic Specifications

Main components of the device:

  • Stand base with a 6 mm lead shield
  • Cylindrical lid with a 6 mm lead shield, with a tapered opening serving for inserting a needle into the vial
  • Lid holder with a syringe needle clamping jaw and with an extra 5 mm lid shield, with a set of spacers to be placed under the vial and under the clamping jaw
  • Lid holder without the clamping jaw, with no spacers
  • Slid cover with a 3 mm lead shield for a 2 ml or 5 ml syringe

Main dimensions:

  • Maximum total height: (5 ml cover) 165 mm
  • Maximum width: 68 mm
  • Maximum length: 110 mm
  • Maximum vial diameter: 26 mm
  • Maximum vial height: 58 mm

Basic weight:

  • Base: 540 g
  • Lid: 250 g
  • Lid holder with clamp: 250 g
  • Total: 1040 g

Accessories Supplied with the Device

Set of spacers to be used under the vial
Set of distance pieces to be used under the jaw
1 socket wrench for the clamping screw on the jaw with internal hexagon no.5

News and Events

  • EANM'15 Hamburg, DE
    Thursday, 13 August 2015
    On October 11 - 13, 2015     We are proud to present our latest products at EANM 28th Annual Congress…
  • SNMMI 2014 Annual Meeting, USA
    Wednesday, 14 May 2014
    SNMMI 2014 Annual Meeting Society of Nuclear Medicine and Molecular Imaging 2014 Annual Meeting June 7-11, 2014, St. Louis, Missouri,…
  • 14 th Congress of the Polish Society of Nuclear Medicine
    Wednesday, 14 May 2014
    14th Congress of the Polish Association of Nuclear MedicineMay 28-30, 2014 Lublin, Poland     Lynax will be present at…
  • ESRR'14 Pamplona
    Thursday, 17 April 2014
    ESRR'1417th European Symposium on Radiopharmacy and Radiopharmaceuticals April 24-27, 2014 Pamplona, Spain
    Read more »
  • Non-Magnetic Syringe Shield for PET-MR
    Sunday, 27 October 2013
    Lynax has been first on the market offering this material and syringe shields especially. Non-magnetic Tungsten syringe shield is necessary…
News and Events archive