PT 318 R2 - Transport container

PT 318 R2 - Transport container

The device provides safe and simple method of handling a vial containing radioactive solution. As a portable shield the device is suitable for usage in the automatic batching and measuring device PT317R3.

Device Design, Purpose & Usage

The device is used in medicine for transporting radionuclide solutions manually. Its purpose is to reduce the risk of exposure and contamination of employees handling radioactive solutions. The device provides a safe and simple method of handling vials containing radioactive solutions.

The vial is inserted freely into the container well and covered by a lid with a lock the lid being equipped with a screw ensuring the safe sealing of the inner space of the container. Swivelling handles serve to carry the container. As a portable shield, the device is suitable for usage in PT317R3Automatic Batching and Measuring device.

Brief Description of the Device, Basic Specifications

Main components of the device:

  • Container base with a 28mm tungsten shield, with fixed stainless-steel handles
  • Lid with a handle, with a 28mm tungsten shield

Related devices:

(Are not a part of this device)

PT317R3 Automatic Batching and Measuring device

Main dimensions:

  • Maximum total height 133 mm
  • Maximum total height without handel 114 mm
  • Container outer diameter 97 mm
  • Container outer diameter 85 mm
  • Maximum vial diameter 26 mm (could be modified)
  • Maximum vial height 59 mm

Total weight

10,5 kg

Accessories Supplied with the Device

  • none

News and Events

  • EANM'15 Hamburg, DE
    Thursday, 13 August 2015
    On October 11 - 13, 2015     We are proud to present our latest products at EANM 28th Annual Congress…
  • SNMMI 2014 Annual Meeting, USA
    Wednesday, 14 May 2014
    SNMMI 2014 Annual Meeting Society of Nuclear Medicine and Molecular Imaging 2014 Annual Meeting June 7-11, 2014, St. Louis, Missouri,…
  • 14 th Congress of the Polish Society of Nuclear Medicine
    Wednesday, 14 May 2014
    14th Congress of the Polish Association of Nuclear MedicineMay 28-30, 2014 Lublin, Poland     Lynax will be present at…
  • ESRR'14 Pamplona
    Thursday, 17 April 2014
    ESRR'1417th European Symposium on Radiopharmacy and Radiopharmaceuticals April 24-27, 2014 Pamplona, Spain
    Read more »
  • Non-Magnetic Syringe Shield for PET-MR
    Sunday, 27 October 2013
    Lynax has been first on the market offering this material and syringe shields especially. Non-magnetic Tungsten syringe shield is necessary…
News and Events archive